Barricade™ Subfloor Air Plus Installation

Preparation

The concrete floor and foundation should be relatively dry and free of large cracks, excessive moisture penetration or flooding problems prior to installing Barricade Subfloor Air Plus panels. Barricade is not meant to be a replacement for good foundation maintenance. Any moisture issues including leaks, excessive moisture, mold/musty spots, foundation cracks, window leaks, exterior drainage or hydrostatic pressure issues, should be resolved prior to Barricade Subfloor Air Plus’s installation to avoid potential contamination to the finished project and surrounding building materials. Any dips or low spots in the concrete surface greater than 1/4″ should be trowelled level with a Portland cement compound or leveled with a self-leveling compound to ensure an accurate installation. Determine the number of Barricade Subfloor Air Plus panels and leveling kits needed to complete the room(s). To do this, calculate the total number of square feet of your floor (length x width). Divide the number by 3.3. This formula allows for a percentage of additional panels normally used as partial waste, while cutting around pipes and other obstacles. Please note: The actual panel dimensions are 3/4″ x 23.5″ x 23.5″. Check out the Barricade Subfloor Air Plus Calculator!

Subfloor panel preparations

Installation tools needed

Installation

The Leveling Kit

  1. The leveling shims have been designed for use with the Barricade Subfloor Air Plus panels for areas where your basement floor is uneven. They simply fit over the cleats on the underside of the Barricade Subfloor panels, raising the panels to the desired level.
  2. Place the leveling shims over the area of the panel where you feel the height adjustment is necessary. Slide the square until it 'nests' or 'cups' into place on the underside of Barricade Subfloor Air plus panel.
  3. In some cases, you may need to stack 2, 3 or more leveling squares together to get the right height adjustment needed to level the panel. NOTE: Any dips or low spots in the concrete surface greater than 1/4 should be trowelled level with a Portland cement-based compound.

The Leveling Kit

  1. The leveling shims have been designed for use with the Barricade Subfloor Air Plus panels for areas where your basement floor is uneven. They simply fit over the cleats on the underside of the Barricade Subfloor panels, raising the panels to the desired level.
  2. Place the leveling shims over the area of the panel where you feel the height adjustment is necessary. Slide the square until it 'nests' or 'cups' into place on the underside of Barricade Subfloor Air plus panel.
  3. In some cases, you may need to stack 2, 3 or more leveling squares together to get the right height adjustment needed to level the panel. NOTE: Any dips or low spots in the concrete surface greater than 1/4 should be trowelled level with a Portland cement-based compound.

NOTE: If panels are to remain unfinished for a period of 2 weeks or longer it is recommended to seal BARRICADE™ Air Plus panels with two coats of polyurethane to protect from moisture.